Monitoring fermentationFR Suivre la fermentationTR Fermantasyonu izlemek
Density is the main signal of how far a fermentation has gone.
Hydrometers are read by hand once or twice a day; vibrating U-tube or Coriolis density meters work in pump-over lines; pressure sensors in the tank give weight loss, or average density from two sensors at different heights. The CO2 release rate shows how fast the fermentation is going.
Technology: Most industrial systems still monitor only temperature; electronic noses and tongues are mostly research tools.